What the pattern looks like
A ceiling under a slow roof leak, a wall beside a leaking shower valve or a floor near a dishwasher supply line can show on a thermal image as a cool, irregular patch with blotchy or tide-line edges. The shape does not follow the framing. It often has a clear source: a bathroom above, a plumbing wall, a chimney, a skylight, a roof valley or an exterior corner.
This is the image people mean when they say a thermal camera "found a leak".
Why wet materials can read cool
Fluke's guidance for moisture work puts it plainly: a thermal imager does not detect moisture. It measures surface temperature. Wet building materials often appear cooler than dry ones because water evaporating from the surface takes heat with it, an effect called evaporative cooling. Water also stores more heat than drywall or wood, so a wet area warms and cools more slowly than the dry material around it. The National Institutes of Health's facilities office calls that second effect thermal lag. Depending on the time of day and what heated the surface, a wet patch can read cooler or warmer than its surroundings.
The Snell Group, a thermography training firm, adds that a camera alone cannot detect and confirm moisture, or mold. It locates thermal patterns that may be associated with moisture, and the thermographer then confirms them with a moisture meter.
What else produces the same pattern
Missing or displaced insulation. On a cold day a gap in attic insulation above a ceiling reads cool and can look like a stain. Fluke's moisture note warns that moisture and missing insulation can look the same on a cold day. See attic insulation gaps.
Air leakage. Cold air entering at a ceiling edge or a light fixture cools the surface. See air leakage at wall tops and ceiling edges.
Cold surfaces near exterior corners. Corners read cold by geometry. See cold corners and condensation.
Air conditioning. A supply register blowing on a ceiling cools it in a pattern that can look like a stain.
How it is confirmed
With a moisture meter. A pin meter measures moisture content at the point of the pins; a pinless meter reads a shallow area through the surface. The usual method is to take readings in the cool patch and in a nearby area of the same material that reads normal, and compare. A meter reading that is elevated compared with the dry reference confirms the camera's suggestion. A normal reading points to one of the look-alikes. The Minnesota Department of Administration's guidance on water intrusion surveys says the same: the determination that a material is indeed wet needs to be made with a moisture meter.
If a reading confirms moisture, the next question is the source, and that is a plumbing, roofing or building envelope question that a thermal image cannot answer. The guide to confirming a thermal finding sets out the sequence.
What New Hampshire rules say about moisture and mold
New Hampshire's home inspection standards of practice do not require thermal imaging or moisture meters. Separately, RSA 310-A:189-b, in effect since January 1, 2016, says no person may perform residential mold assessment services for pay without a national third-party certification, with an exemption for professionals whose primary contracted work is not mold assessment. A home inspector who reports a wet area is reporting moisture, not assessing mold.
Common mistakes
Cutting drywall on the strength of the image alone. Confirm with a meter first.
Scanning once. A slow leak may be dry on the day of the scan, and a ceiling under a roof leak may be wet only after rain. A dry reading does not clear the history.
Ignoring old stains. A visible stain that reads dry and normal on the camera may be an old, repaired leak. It is still a question for the seller.
What to do with it
If the patch is confirmed wet, find the source before repairing the finish. Check the plumbing above, the roof over it, and any exterior wall penetrations nearby. If the patch reads dry, ask the thermographer which look-alike it is. For a buyer, a confirmed wet area is a question for the seller about the source and any repairs.
Where the guidance comes from
Fluke's application note Using thermal imaging for moisture detection and The Snell Group's basics of using infrared for building moisture inspections set out the method and its limits. The certification requirement is RSA 310-A:189-b.