The short answer
New Hampshire licenses home inspectors and sets standards of practice for them, and those standards do not mention thermal imaging. Thermography itself has its own standards, written by ASTM, ISO, NFPA and NETA for particular jobs, none of which a home inspection must follow. And thermographers are certified privately, at levels that range from a short course to multi-week programs. A thermal image in an inspection report is therefore only as good as the method and training behind it. This section sets out all three layers.
The state layer
Under RSA 310-A:189, a license from New Hampshire's Board of Home Inspectors has been required since January 1, 2010. The board's standards of practice, in Home 600 of the administrative rules and last revised effective August 18, 2024, require a visual examination of readily accessible systems and components and include limitations relevant to thermal work: no measuring of amperage, voltage or impedance; no determining efficiency; no identifying concealed conditions or latent defects; and no requirement to perform actions not specifically stated. See New Hampshire home inspections and infrared.
The standards layer
ASTM C1060 covers qualitative inspection of insulation in frame buildings and says proof of missing insulation requires independent validation. ASTM E1186 covers locating air leakage sites, including with a blower door. ASTM C1153 covers night surveys of wet insulation in low-slope roofs, verified by cores. ISO 6781-1:2023 sets requirements for thermographic services in buildings, including qualifications and reporting. NFPA 70B and the NETA criteria govern electrical maintenance thermography in facilities. See thermography standards for buildings.
The people layer
Thermography certification is private. Level I, II and III programs follow ASNT and ISO outlines; home inspector associations offer shorter residential courses. New Hampshire has no separate thermographer credential. See thermographer training and certification.
What this means for a buyer
Before the inspection, ask whether the inspector will use a thermal camera, on what, and under what conditions. After it, read each thermal image for three things: what pattern it shows, what conditions it was taken under, and what confirmed it. A thermal image of an attic insulation gap that the inspector then looked at in the attic is a finding. A thermal image of a cool patch on a ceiling with no moisture reading is a lead. A thermal image of a hot breaker is a referral to an electrician.
Common misreadings
"Infrared inspection" as a defined service. No New Hampshire rule defines what an infrared inspection includes. One inspector may scan every room under good winter conditions; another may take a few images of the panel and the ceilings. Ask what was scanned and under what conditions.
A standard as a guarantee. Naming ASTM C1060 or ISO 6781-1 tells you what method a thermographer says they followed. It does not tell you the conditions on the day or whether the findings were confirmed.
Certification as accuracy. Training improves method, but no certificate makes a camera see moisture or makes a panel show a bad connection without load.
A thermal image as part of the inspection report's required content. In New Hampshire, the report covers what the standards of practice require. Thermal images are additional, and the inspector's agreement and report should say what they are for.
An energy audit as a home inspection, or the reverse. An energy audit measures how a house uses and loses energy, usually with a blower door. A home inspection reports on the condition of systems and components. A thermal camera can appear in either, for different purposes.
Guides in this section
- New Hampshire home inspections and infrared: the license, the standards of practice and where infrared fits.
- Thermography standards for buildings: ASTM C1060, E1186 and C1153, ISO 6781-1, NFPA 70B and NETA.
- Thermographer training and certification: what the levels mean and what to ask.
Where the rules come from
RSA 310-A:189 and the Home 100-700 rules; ASTM's summaries of C1060-23, E1186-22 and C1153-23; ISO's listing for ISO 6781-1:2023.