What the pattern looks like
Plumbing in walls and floors shows on a thermal image only when it differs in temperature from its surroundings. Run the hot water for a minute and the hot supply lines appear as warm lines on the wall or floor, tracing the route from the water heater to the fixture. A leak from a hot line can show as a warm bloom spreading from the pipe, or a warm stain running down the wall below it.
Cold supply lines and drains behave differently. A cold line may show as a faint cool line, and a leak from it usually shows only as a cool, irregular patch where wet material is evaporating. A slow drain leak under a tub or shower may show nothing until the floor or ceiling below has been wet for some time.
Why the camera is useful here
Without a camera, finding the path of a pipe in a finished wall means guessing from fixture locations. With hot water running, the thermographer can see the pipe route and where it changes direction. The HUD research office notes the same use in its overview of thermal imaging for building diagnostics: hot-water lines in a plumbing manifold can be identified and labeled with a camera.
That narrows the search. It does not find the leak by itself.
What the camera cannot do
It cannot read moisture. Fluke's moisture guidance states that a thermal imager does not detect moisture; wet materials often appear cooler because of evaporative cooling, and a moisture meter is used to verify that moisture is causing the temperature difference.
It cannot see a leak that has not yet wet a surface. A drain that leaks only when the tub is emptied, or a supply fitting that weeps under pressure only when a valve is opened, may need to be run before the scan.
It cannot see inside a slab with any precision. A hot water leak under a slab floor can show as a warm area on the floor surface, but the heat spreads through concrete, so the image gives a general area rather than a point.
What else produces a similar pattern
Radiant floor heat and hydronic piping. Heating pipes are warm by design and can look like a leak if the thermographer does not know they are there. See radiant floor heat patterns and hydronic baseboard and heating pipes.
Condensation on cold pipes. In summer, cold water lines in humid basements sweat and wet nearby material. That is a humidity problem, not a leak.
A wet patch from another source. A cool patch under a bathroom can also be a roof or window leak entering from above. See a cool patch on a ceiling or wall.
How it is confirmed
Take moisture meter readings at the patch and at a dry reference spot. If moisture is confirmed, isolate the source: run the hot water, then the cold, then fill and drain the fixture, and watch whether the pattern grows. A plumber may also use a pressure test on supply lines, or an acoustic leak detector. Access through a cabinet, a basement ceiling or a small opening confirms the leak itself.
Common mistakes
Assuming a warm line is a leak. Most warm lines are pipes doing their job.
Scanning without running water. A dry, idle system shows little.
Repairing the stain, not the source. Paint over a stain from an active leak and it will return.
What to do with it
For a buyer, a confirmed wet area near plumbing is a question for the seller and a plumber, and the inspection report should say whether moisture was measured. For an owner, ask the plumber to confirm the source before opening the wall, and use the image to choose where to open it. The guide to confirming a thermal finding sets out the order of checks.
Where the guidance comes from
The limits of thermal imaging for moisture are described in Fluke's moisture detection application note. HUD's research office describes identifying hot-water lines in Thermal Imaging for Building Diagnostics.