Overview
The seventeen patterns on this site fall into four families, grouped by what makes them. The grouping is the fastest way to judge what conditions a pattern needed and what will confirm it, because the cause decides both.
The first two families are made by the building shell. Insulation and framing patterns come from heat conducting through walls and ceilings; air leakage patterns come from air moving through gaps. Both need a steady difference between indoor and outdoor temperature, and both are clearest in a New Hampshire winter. The third family, moisture, is made by water: evaporation cools a wet surface, and wet materials hold heat longer than dry ones. The fourth family is made by the house's own heat sources: electrical connections under load, heating pipes, radiant floors and ducts.
Families also tell a reader what to ask about the conditions. For the shell families, ask about the temperature difference and how long it had been steady. For moisture, ask what heated or cooled the surface and whether a meter was used. For electrical and mechanical patterns, ask what was running.
Why the cause matters
A pattern whose cause is known can be checked with the right tool. A conduction pattern is checked by looking into the cavity or the attic. An air leak is checked by comparing images with a blower door running, or with smoke. A moisture pattern is checked with a meter. An electrical pattern is checked by an electrician with a meter and a torque driver. A reader who knows the family knows which of those to ask for.
The cause also explains the look-alikes. Patterns from different families can look the same on a screen: a cool ceiling patch can be moisture, a conduction gap or an air leak. Each pattern page lists the look-alikes from the other families, which is often where a misreading starts.
Using the families to read an image
A practical way to read a thermal image is to ask which family its pattern most likely belongs to, then what conditions that family needs, then whether those conditions were met, and only then what the pattern means. Shape helps: crisp edges that follow the framing point to conduction; feathered streaks to air; irregular blotches to moisture; lines and points to pipes, ducts and wiring.
The weight scale and the families are independent. A conduction pattern can be a strong signal (an attic gap) or need confirming (settled insulation); a systems pattern can be a strong signal (a radiant floor) or easily misread (a warm dimmer). Reading both together gives the fullest picture.
Families across the seasons
In New Hampshire the families also sort by season. The two shell families are winter patterns: the heating season gives the steady temperature difference they need, and roof snowmelt only appears with snow. Moisture patterns can appear in any season, though spring melt and summer storms bring the leaks that create them, and summer humidity brings condensation on cold pipes. Systems patterns follow use: heating patterns show when the heat runs, electrical patterns when the load is on. A thermal image's date is part of its meaning.
Families and the people who confirm them
Each family also points to the person who confirms it. Conduction and air leakage patterns go to an energy auditor or an insulation contractor, ideally with a blower door. Moisture patterns go to whoever can find the source: a plumber, a roofer or a builder. Electrical patterns go to a licensed electrician. Heating patterns go to a heating technician. A thermal report that names the family of each finding has, in effect, already said who should look next.
The four families
Insulation and framing: 4 patterns
Missing wall insulation, settled insulation, attic insulation gaps and framing thermal bridging are conduction patterns. They follow the framing and need a steady indoor-outdoor temperature difference to appear.
Air leakage: 4 patterns
Air leakage at top plates, windows and doors, and the rim joist, together with roof snowmelt, are patterns made by air moving through the shell. A blower door makes them clearer.
Moisture: 4 patterns
A cool patch on a ceiling, hidden plumbing leaks, cold corners and wet roof insulation are patterns a camera can suggest but never confirm. A meter or a core decides.
Electrical and mechanical: 5 patterns
Hot breakers, warm outlets, radiant floors, hydronic baseboard and duct leaks are made by the house's own heat sources, and depend on load or on the system running.