House Thermography Reference logo — a house outline shaded from cold to warmHouse Thermography ReferenceWhat an infrared image of a house shows, and what it cannot
Topic hub · 3 guides

After the scan: confirming a thermal finding and deciding what to do about it

A thermal image starts a process. The useful part comes after: confirming what the pattern means, measuring what the camera cannot, and fixing causes rather than symptoms.

The short answer

Every thermal finding leads to one of three next steps. Some need confirming: moisture with a meter, insulation by looking, electrical heat by an electrician. Some need measuring: air leakage across a whole house is measured with a blower door, and duct leakage with a separate calibrated test. And some need tracing to a cause: a roof that sheds snow in patches or builds ice dams is usually reporting heat lost from the living space. This section covers all three.

Confirming

The standards build confirmation in. ASTM C1060 says proof of missing insulation requires independent validation. ASTM C1153 includes verifying roof moisture findings with invasive tests. Camera makers and trainers say a thermal camera cannot detect moisture and that a moisture meter confirms it. See confirming a thermal finding.

Measuring

A thermal camera shows where air leaks; it does not say how much. A blower door depressurizes the house so leaks show clearly on the camera and measures overall leakiness at the same time. ASTM E1186 describes the combination, and New Hampshire's utility-run NHSaves audits use diagnostic tests to locate air leaks. See blower door and infrared testing.

Tracing to a cause

Ice dams are the clearest New Hampshire example. Heat from the house, through air leaks, thin insulation and attic ducts, warms the upper roof while the eaves stay frozen. The fix is in the attic, not on the roof. See ice dams and attic heat loss and warm roof patches, snowmelt and ice dams.

For buyers and owners

For a buyer, the question is whether a finding is a defect, a maintenance item or an upgrade opportunity, and whether it changes the price or the decision. A confirmed active leak is a repair question for the seller. A drafty house with thin attic insulation is an upgrade with a cost and a payback. For an owner, the question is order: seal before insulating, confirm before opening walls, and fix sources before finishes.

Common misreadings

Treating the image as the repair scope. A thermal image shows where to look. The scope of a repair comes from what the look finds: a meter reading, an open cavity, an electrician's measurements or a core.

Fixing the finish first. Painting over a stain, patching a ceiling or adding heat cables at the eaves deals with what shows, not what causes it. Find and fix the source, then the surface.

Insulating before sealing. Energy programs seal air leaks first, especially at the top and bottom of the house, because insulation laid over an open hole does little to stop air.

Assuming one dry reading clears a history. A roof leak can be dry on a sunny day and a slow plumbing leak can be dry between uses. Past stains and repairs remain questions for the seller even when today's reading is normal.

Skipping the after picture. A second thermal image after the work, taken under similar conditions, is the simplest record that insulation was filled, a leak sealed or a duct reconnected.

Who does what after a scan

The thermographer or inspector who took the image explains what it shows and what conditions it was taken under. A licensed electrician deals with hot connections and warm devices. A plumber deals with confirmed leaks. A roofer deals with roof leaks and, on low-slope roofs, with wet insulation found by a survey and confirmed by cores. A heating technician deals with cold zones, boilers and ducts. An energy auditor measures air and duct leakage and plans air sealing and insulation. Knowing which person a finding goes to is often the most useful thing a reader can take from a thermal report.

Guides in this section

Where the guidance comes from

ASTM's summaries of C1060-23, E1186-22 and C1153-23; the NHSaves Home Energy Performance brochure; the University of Minnesota Extension on ice dams.

Frequently Asked Questions

What should happen after a thermal scan finds something?

Confirm it with the right check for that kind of finding, then decide whether it is a defect, maintenance or an upgrade.

Does a thermal scan measure how leaky my house is?

No. A blower door test measures overall leakiness; the camera shows where the leaks are.

Where should I start if my house gets ice dams?

In the attic: air sealing the ceiling, then insulating, and checking any ducts or bath fans there.