House Thermography Reference logo — a house outline shaded from cold to warmHouse Thermography ReferenceWhat an infrared image of a house shows, and what it cannot
EntityMap v1.0

House Thermography Reference Entity Map

This is the machine-readable knowledge map for House Thermography Reference, published to the EntityMap v1.0 specification. It describes the site's key entities — the 17 thermal patterns covered here, the standards and sources they depend on, and the categories and families that organize them — with evidence passages drawn from its pages and links to the open knowledge graph.

View the EntityMap JSON → (40 entities · EntityMap v1.0)

Thing

Missing Wall Insulation

The clearest pattern in building thermography, with crisp edges at the studs. It needs a steady indoor-outdoor difference, and ASTM C1060 still asks for proof.

Relations:

  • PART_OF → Insulation and framing

On an interior thermal image taken in winter, an insulated wall shows a fairly even surface with the studs, plates and headers drawn as slightly cooler lines. That faint framing grid is normal. A missing insulation pattern is different: one whole stud bay, or several, reads distinctly colder than the bays beside it, with crisp vertical edges where the studs bound it and often a fairly square top and bottom at the plates or a fire block. From outside on a cold night the same cavity reads warmer than its neighbors, because heat is escaping through it.

Missing Wall Insulation | House Thermography Reference — published by House Thermography Reference
Thing

Settled or Compressed Insulation

Loose fill slumps and leaves a gap at the top of the cavity. Air leaking at the top plate looks much the same, so a look into the cavity settles it.

Relations:

  • PART_OF → Insulation and framing

Loose-fill insulation blown into a wall cavity can settle over the years, leaving an uninsulated gap at the top. On an interior winter image that gap appears as a cold band running across the top of the stud bays, sometimes a few inches deep, sometimes a foot or more. Below the band the wall reads evenly. Because every bay was filled the same way, the band often repeats across a whole wall at a similar depth, which is what separates it from random cold spots. Batt insulation produces a different version.

Settled or Compressed Insulation | House Thermography Reference — published by House Thermography Reference
Thing

Gaps in Attic Insulation

Easy to see and easy to check, because the attic can be entered. New Hampshire inspectors must report missing insulation in unfinished spaces.

Relations:

  • PART_OF → Insulation and framing

From the living space on a winter day, a ceiling under a well-insulated attic reads evenly warm, with the joists drawn faintly. A gap in the insulation above appears as a cold patch whose shape tells you the cause. A square cold patch in a hallway ceiling is usually an uninsulated attic hatch. A ring of cold around a recessed light is often insulation held back from a fixture. A cold strip along an exterior wall is the shallow insulation at the eaves.

Gaps in Attic Insulation | House Thermography Reference — published by House Thermography Reference
Thing

Framing Thermal Bridging

Normal in every frame wall. Its presence shows the conditions were good enough to see real problems; its absence on a mild day proves little.

Relations:

  • PART_OF → Insulation and framing

A thermal image of an insulated wall in winter, taken from inside, usually shows a ladder of faint lines: studs every 16 or 24 inches, a double plate at the top, a single plate at the bottom, and thicker bands above windows and doors where the headers are. The corners, where three or more studs meet, show as wider cold strips. This is thermal bridging : heat taking the easier path through solid wood instead of through the insulated cavities between. The U.S.

Framing Thermal Bridging | House Thermography Reference — published by House Thermography Reference
Thing

Air Leakage at Wall Tops and Ceiling Edges

Air leaks draw soft, irregular streaks rather than square bays. A blower door makes them grow, which is how they are told apart from insulation gaps.

Relations:

  • PART_OF → Air leakage

When cold outside air or attic air leaks into a heated room in winter, it cools the surfaces it passes. On a thermal image this shows as irregular streaks, often called fingers or feathering, spreading from the source. Along the top of an exterior wall the streaks hang down from the ceiling line. At an interior wall they can show where cold attic air drops down the wall cavity through the open top plate. Around a ceiling light, a fan box or a plumbing vent the cold spreads outward from the hole.

Air Leakage at Wall Tops and Ceiling Edges | House Thermography Reference — published by House Thermography Reference
Thing

Air Leakage at Windows and Doors

The most drafts and the most false alarms. Cold glass, cold glass edges and reflections all look like leaks until the camera moves.

Relations:

  • PART_OF → Air leakage

A leaking window or door in winter shows on an interior thermal image as cold air spilling from a joint. Typical shapes are a cold tongue running down the wall below a sash, a cold strip along the meeting rail of a double-hung window, a fan of cold spreading across the floor from under an exterior door, or cold streaks around the casing where the gap between the window frame and the rough opening was never sealed. As with all air leakage, the edges are soft and the shape follows the air. The most drafts and the most false alarms.

Air Leakage at Windows and Doors | House Thermography Reference — published by House Thermography Reference
Thing

Rim Joist and Sill Heat Loss

One of the leakiest, least insulated parts of many New England houses, and one of the easiest to see and fix from an unfinished basement.

Relations:

  • PART_OF → Air leakage

The rim joist (also called the band joist) is the board that caps the ends of the floor joists around the perimeter of a house, sitting on the sill plate , which sits on the foundation. From inside an unfinished basement in winter, a thermal camera usually shows the whole rim as a cold band, with colder spots where the sill meets the concrete and where pipes, wires or dryer vents pass through. From the first floor, the same heat loss and air leakage can show as a cold strip along the base of exterior walls or under baseboards.

Rim Joist and Sill Heat Loss | House Thermography Reference — published by House Thermography Reference
Thing

Warm Roof Patches, Snowmelt and Ice Dams

The roof shows where heat escapes; the attic shows why. The same heat builds ice dams at the eaves through a New Hampshire winter.

Relations:

  • PART_OF → Air leakage

From outside on a cold, still night, a thermal image of a pitched roof over a well-insulated, well-sealed attic reads cold and fairly even, close to the night sky's influence. Warm patches show where heat from the house is reaching the roof deck: a stripe above a ridge where warm air leaks through, rectangles above a bathroom fan or an uninsulated hatch, streaks above a chimney chase or a duct run. After a snowfall the same pattern appears without a camera.

Warm Roof Patches, Snowmelt and Ice Dams | House Thermography Reference — published by House Thermography Reference
Thing

A Cool Patch on a Ceiling or Wall

The classic leak image. The camera cannot detect moisture, and missing insulation looks the same on a cold day. A moisture meter decides.

Relations:

  • PART_OF → Moisture

A ceiling under a slow roof leak, a wall beside a leaking shower valve or a floor near a dishwasher supply line can show on a thermal image as a cool, irregular patch with blotchy or tide-line edges. The shape does not follow the framing. It often has a clear source: a bathroom above, a plumbing wall, a chimney, a skylight, a roof valley or an exterior corner. This is the image people mean when they say a thermal camera "found a leak". The classic leak image. The camera cannot detect moisture, and missing insulation looks the same on a cold day.

A Cool Patch on a Ceiling or Wall | House Thermography Reference — published by House Thermography Reference
Thing

Hidden Plumbing Leaks

Running the hot water lights up the pipe route and narrows the search. The leak itself is confirmed with a meter and access to the line.

Relations:

  • PART_OF → Moisture

Plumbing in walls and floors shows on a thermal image only when it differs in temperature from its surroundings. Run the hot water for a minute and the hot supply lines appear as warm lines on the wall or floor, tracing the route from the water heater to the fixture. A leak from a hot line can show as a warm bloom spreading from the pipe, or a warm stain running down the wall below it. Cold supply lines and drains behave differently.

Hidden Plumbing Leaks | House Thermography Reference — published by House Thermography Reference
Thing

Cold Corners and Condensation Risk

Every exterior corner reads cold in winter. It matters only when the surface approaches the dew point of the room's air.

Relations:

  • PART_OF → Moisture

On an interior thermal image in winter, the corner where two exterior walls meet reads colder than the walls on either side, as a vertical band. Where that corner meets the ceiling, a cold triangle often appears. The ceiling edge along every exterior wall may show a cold strip. Behind furniture placed against an exterior wall, and inside closets on exterior walls, surfaces read colder than in the open room. These patterns appear in well-built houses. Every exterior corner reads cold in winter.

Cold Corners and Condensation Risk | House Thermography Reference — published by House Thermography Reference
Thing

Wet Insulation in a Low-Slope Roof

Wet insulation holds the day's heat into the night. ASTM C1153 surveys find it, and cores confirm it before anything is replaced.

Relations:

  • PART_OF → Moisture

Most houses in New Hampshire have pitched roofs, but many have a low-slope section: a porch roof, a dormer, a garage, a flat-roofed addition, or a condominium building. On a low-slope roof with insulation laid on the deck under a membrane, wet insulation shows on a night-time thermal image as warm patches against the cooler dry roof. The patches often have defined edges, because water spreads along board joints and stops at seams, and they frequently sit near drains, curbs, penetrations and parapets. Wet insulation holds the day's heat into the night.

Wet Insulation in a Low-Slope Roof | House Thermography Reference — published by House Thermography Reference
Thing

A Hot Breaker or Connection

One of the most useful thermal findings, and the most load-dependent. A panel with nothing running can look perfect and still have a bad connection.

Relations:

  • PART_OF → Electrical and mechanical

With the dead front (the inner cover) of a panel removed, a thermal image shows breakers, bus connections, lugs and wire terminations. Under load, conductors and breakers run warm, and breakers carrying similar current should look similar. A finding stands out as one breaker, one terminal screw or one lug distinctly hotter than the others, often with heat spreading along the wire from the hot point. With the dead front on, only the surface of the cover is visible, and a hot spot shows only as a faint warm area on the metal or plastic, if at all.

A Hot Breaker or Connection | House Thermography Reference — published by House Thermography Reference
Thing

Warm Outlets, Switches and Fixtures

Dimmers, smart switches and loaded receptacles run warm by design. A device hot with little on it is the one to call an electrician about.

Relations:

  • PART_OF → Electrical and mechanical

On a thermal image of a wall, a working receptacle or switch is usually close to wall temperature. Several common devices are warmer. Dimmer switches convert some energy to heat in their electronics and often feel warm to the touch. Smart switches, timers and USB receptacles contain electronics. A receptacle feeding a space heater, a hair dryer or a window air conditioner carries real current and warms up. Plug-in transformers and chargers are warm.

Warm Outlets, Switches and Fixtures | House Thermography Reference — published by House Thermography Reference
Thing

Radiant Floor Heating Patterns

The clearest map of the tubing comes as the floor warms from cold. Essential before drilling, and a quick check that every loop is flowing.

Relations:

  • PART_OF → Electrical and mechanical

A hydronic radiant floor, with warm water circulating through tubing in a slab, a thin topping or under the subfloor, shows on a thermal image as parallel warm lines or a serpentine pattern, sometimes closer together near exterior walls, all leading back to a manifold. An electric radiant mat under tile shows as tight parallel lines of cable. When the system is working well and has been on for a while, the floor reads more evenly warm and the lines blur. The clearest map of the tubing comes as the floor warms from cold.

Radiant Floor Heating Patterns | House Thermography Reference — published by House Thermography Reference
Thing

Hydronic Baseboard and Heating Pipes

Hot water heat reads well: working emitters show warm and cold ones stand out. The camera says nothing about the boiler's combustion or safety.

Relations:

  • PART_OF → Electrical and mechanical

Hot water (hydronic) heating, with a boiler circulating water through baseboard convectors, cast-iron radiators or radiant tubing, is common in New Hampshire. With the system calling for heat, a thermal image shows every working emitter as warm: baseboard runs as long warm bands at the base of walls, radiators as warm blocks, and the pipes feeding them as warm lines along basement ceilings, up walls and across floors. At the boiler, the supply pipe reads hotter than the return, since the water gives up heat on its way around.

Hydronic Baseboard and Heating Pipes | House Thermography Reference — published by House Thermography Reference
Thing

Duct Leaks and Disconnected Ducts

A disconnected attic duct heats the attic instead of the room and feeds ice dams. The camera finds suspects; a duct test measures the loss.

Relations:

  • PART_OF → Electrical and mechanical

Forced-air heating and cooling move air through ducts to registers. With the system running, a thermal image shows the ducts themselves warm in heating mode (or cool in cooling mode) and the registers warm where air leaves. A leak shows as a plume of warm air spreading from a joint, a boot or a seam into an attic, a basement or a wall cavity. A disconnected duct shows as a large warm area in the attic and a register in the room below that delivers little air.

Duct Leaks and Disconnected Ducts | House Thermography Reference — published by House Thermography Reference
Taxonomy

Heat Loss and Air Leakage Patterns

Thermal patterns made by the building shell: missing and settled insulation, attic insulation gaps, framing thermal bridging, air leakage at top plates, windows, doors and rim joists, and roof snowmelt. All need a steady indoor-outdoor temperature difference.

Relations:

  • INCLUDES → Missing Wall Insulation
  • INCLUDES → Settled or Compressed Insulation
  • INCLUDES → Gaps in Attic Insulation
  • INCLUDES → Framing Thermal Bridging
  • INCLUDES → Air Leakage at Wall Tops and Ceiling Edges
  • INCLUDES → Air Leakage at Windows and Doors
  • INCLUDES → Rim Joist and Sill Heat Loss
  • INCLUDES → Warm Roof Patches, Snowmelt and Ice Dams

Thermal patterns made by the building shell: missing and settled insulation, attic insulation gaps, framing thermal bridging, air leakage at top plates, windows, doors and rim joists, and roof snowmelt. All need a steady indoor-outdoor temperature difference.

Heat Loss and Air Leakage on Thermal Images | House Thermography Reference — published by House Thermography Reference
Taxonomy

Moisture and Building Systems Patterns

Thermal patterns made inside the house: possible moisture on ceilings and walls, hidden plumbing leaks, cold corners, wet roof insulation, hot electrical connections, warm devices, radiant floors, hydronic baseboard and duct leaks.

Relations:

  • INCLUDES → A Cool Patch on a Ceiling or Wall
  • INCLUDES → Hidden Plumbing Leaks
  • INCLUDES → Cold Corners and Condensation Risk
  • INCLUDES → Wet Insulation in a Low-Slope Roof
  • INCLUDES → A Hot Breaker or Connection
  • INCLUDES → Warm Outlets, Switches and Fixtures
  • INCLUDES → Radiant Floor Heating Patterns
  • INCLUDES → Hydronic Baseboard and Heating Pipes
  • INCLUDES → Duct Leaks and Disconnected Ducts

Thermal patterns made inside the house: possible moisture on ceilings and walls, hidden plumbing leaks, cold corners, wet roof insulation, hot electrical connections, warm devices, radiant floors, hydronic baseboard and duct leaks.

Moisture and Building Systems on Thermal Images | House Thermography Reference — published by House Thermography Reference
Taxonomy

Insulation and framing

Patterns made by heat conducting through walls and ceilings, where insulation is thin, missing or bypassed by framing: one of the four families of thermal patterns in a house, grouped by what makes them.

Relations:

  • INCLUDES → Missing Wall Insulation
  • INCLUDES → Settled or Compressed Insulation
  • INCLUDES → Gaps in Attic Insulation
  • INCLUDES → Framing Thermal Bridging

Patterns made by heat conducting through walls and ceilings, where insulation is thin, missing or bypassed by framing: one of the four families of thermal patterns in a house, grouped by what makes them.

The Four Families of Thermal Patterns | House Thermography Reference — published by House Thermography Reference
Taxonomy

Air leakage

Patterns made by air moving through the building shell, and the roof snowmelt that follows it: one of the four families of thermal patterns in a house, grouped by what makes them.

Relations:

  • INCLUDES → Air Leakage at Wall Tops and Ceiling Edges
  • INCLUDES → Air Leakage at Windows and Doors
  • INCLUDES → Rim Joist and Sill Heat Loss
  • INCLUDES → Warm Roof Patches, Snowmelt and Ice Dams

Patterns made by air moving through the building shell, and the roof snowmelt that follows it: one of the four families of thermal patterns in a house, grouped by what makes them.

The Four Families of Thermal Patterns | House Thermography Reference — published by House Thermography Reference
Taxonomy

Moisture

Patterns made by wet materials and cold surfaces, which a camera can suggest but never confirm: one of the four families of thermal patterns in a house, grouped by what makes them.

Relations:

  • INCLUDES → A Cool Patch on a Ceiling or Wall
  • INCLUDES → Hidden Plumbing Leaks
  • INCLUDES → Cold Corners and Condensation Risk
  • INCLUDES → Wet Insulation in a Low-Slope Roof

Patterns made by wet materials and cold surfaces, which a camera can suggest but never confirm: one of the four families of thermal patterns in a house, grouped by what makes them.

The Four Families of Thermal Patterns | House Thermography Reference — published by House Thermography Reference
Taxonomy

Electrical and mechanical

Patterns made by the house's own heat sources: wiring under load, heating pipes, radiant floors and ducts: one of the four families of thermal patterns in a house, grouped by what makes them.

Relations:

  • INCLUDES → A Hot Breaker or Connection
  • INCLUDES → Warm Outlets, Switches and Fixtures
  • INCLUDES → Radiant Floor Heating Patterns
  • INCLUDES → Hydronic Baseboard and Heating Pipes
  • INCLUDES → Duct Leaks and Disconnected Ducts

Patterns made by the house's own heat sources: wiring under load, heating pipes, radiant floors and ducts: one of the four families of thermal patterns in a house, grouped by what makes them.

The Four Families of Thermal Patterns | House Thermography Reference — published by House Thermography Reference
Document

Thermal Imaging of Houses: What the Patterns Mean

What infrared images of a house can show and what they cannot: insulation gaps, air leaks, possible moisture, hot connections and heating patterns.

Infrared cameras now turn up in home inspections, energy audits and contractors' trucks across New Hampshire, and their images are vivid enough to look like proof. They are not. A camera reads the temperature of a surface, and many different causes paint the same pattern. This reference takes the 17 patterns a reader most often meets in a thermal image of a house and says, for each one, what it can tell you, what else produces it, and how it is confirmed.

Thermal Imaging of Houses: What the Patterns Mean — published by House Thermography Reference
Document

Thermal Image Patterns in a House: All 17

All 17 patterns on an infrared image of a house, and whether each is a strong signal, needs confirming, or is easily misread.

All 17 patterns on this site, each with its weight stated up front: a strong signal, a finding that needs confirming, or a pattern that is easily misread.

Thermal Image Patterns in a House: All 17 — published by House Thermography Reference
Document

Guides to Thermal Imaging of Houses

Guides to infrared images of houses: emissivity, scan conditions, camera specs, New Hampshire inspection rules, standards, confirmation and ice dams.

The pattern pages answer what one pattern on a thermal image means. These guides answer the questions around them: why shiny surfaces mislead a camera, what weather a scan needs, what camera specifications mean, what New Hampshire's home inspection rules require, which thermography standards exist, what thermographer training covers, how findings are confirmed, why audits pair a blower door with the camera, and how attic heat loss becomes ice dams.

Guides to Thermal Imaging of Houses — published by House Thermography Reference
Document

How Thermal Imaging of a House Works

How an infrared camera reads a house: surface temperature, heat flow, emissivity and reflections, camera specifications, and the weather a useful scan needs.

A thermal camera shows the temperature of surfaces, nothing more. Everything a thermographer concludes about walls, roofs and wiring follows from how heat moved to those surfaces.

How Thermal Imaging of a House Works — published by House Thermography Reference
Document

Infrared in a New Hampshire Home Inspection

Where thermal imaging fits in a New Hampshire home inspection, which standards govern building thermography, and what training thermographers have.

A thermal camera in a home inspection is an extra, governed by the inspector's training and method rather than by the state's rules. Knowing that changes how its images should be read.

Infrared in a New Hampshire Home Inspection — published by House Thermography Reference
Document

After the Thermal Scan: Confirming and Acting

What to do after a thermal scan of a house: confirming findings, using a blower door audit to find air leaks, and tracing ice dams to attic heat loss.

A thermal image starts a process. The useful part comes after: confirming what the pattern means, measuring what the camera cannot, and fixing causes rather than symptoms.

After the Thermal Scan: Confirming and Acting — published by House Thermography Reference
Document

Emissivity and Reflections in Building Thermography

What emissivity is, why shiny metal, glass and foil fool a thermal camera, how reflections create false hot and cold spots, and how thermographers check them.

A thermal camera reads the infrared a surface gives off, plus whatever that surface reflects. On paint and drywall the reading is honest. On shiny metal, glass and foil it often is not.

Emissivity and Reflections in Building Thermography — published by House Thermography Reference
Document

Temperature Difference and Timing for Thermal Scans

Why building thermography needs a steady indoor-outdoor temperature difference, how sun and wind distort images, and when New Hampshire suits a scan.

A thermal camera reads heat flow through a building, and no heat flow means no picture. Most failed building scans fail on conditions, not on the camera.

Temperature Difference and Timing for Thermal Scans — published by House Thermography Reference
Document

Thermal Camera Resolution and Specifications Explained

What infrared resolution, thermal sensitivity (NETD), field of view and spot size mean, how phone cameras differ, and what to ask a thermographer.

Two thermal images of the same wall can differ because of the camera as much as the house. Resolution and sensitivity decide what small problems are visible at all.

Thermal Camera Resolution and Specifications Explained — published by House Thermography Reference
Document

New Hampshire Home Inspections and Thermal Imaging

What New Hampshire's home inspector license and standards of practice require, why thermal imaging is not part of the minimum, and how to read it.

New Hampshire licenses home inspectors and sets standards of practice that say nothing about thermal cameras. An inspector who uses one is going beyond the minimum, and the images should be read that way.

New Hampshire Home Inspections and Thermal Imaging — published by House Thermography Reference
Document

Thermography Standards for Buildings, Explained

What ASTM C1060, E1186 and C1153, ISO 6781-1, NFPA 70B and the NETA temperature criteria each cover, what they require, and which apply to houses.

Building thermography has a small set of standards, each written for one job. Knowing which one a report relies on tells you what its images can and cannot claim.

Thermography Standards for Buildings, Explained — published by House Thermography Reference
Document

Thermographer Training and Certification Levels

What thermography certification levels mean, which standards they follow (ASNT SNT-TC-1A, ISO 18436-7), how inspector courses differ, and what to ask.

No state licenses thermographers. Credentials come from private training bodies, and they range from a few hours online to weeks of classroom and field work.

Thermographer Training and Certification Levels — published by House Thermography Reference
Document

How to Confirm a Thermal Imaging Finding

Why thermal images need confirming, the checks that confirm moisture, insulation, air leak and electrical findings, and what a report should say about them.

A thermal image is a reason to look harder at one spot. The standards say so, the camera makers say so, and the cost of acting on an unconfirmed image says so most clearly.

How to Confirm a Thermal Imaging Finding — published by House Thermography Reference
Document

Blower Door Testing and Infrared Scans Together

How a blower door makes air leaks visible to a thermal camera, what ASTM E1186 says, and how New Hampshire's NHSaves audits use both tests.

A thermal camera shows where heat moves. A blower door makes air move on purpose. Together they turn faint, weather-dependent hints of air leakage into clear patterns.

Blower Door Testing and Infrared Scans Together — published by House Thermography Reference
Document

Ice Dams and Attic Heat Loss in New Hampshire

How heat leaking from a house melts roof snow and builds ice dams, how thermal images trace it to its source, and what fixes the cause.

Ice dams are a New Hampshire winter fixture, and most of them start inside the house. A thermal camera, and sometimes just the snow, shows where the heat gets out.

Ice Dams and Attic Heat Loss in New Hampshire — published by House Thermography Reference
Document

About House Thermography Reference

Who publishes House Thermography Reference, what it rests on, how its pages are researched and dated, and how it handles its one link to the publisher.

House Thermography Reference is a reference on one question: what does a pattern on an infrared image of a house actually tell you? It covers 17 patterns that thermal cameras commonly show in walls, ceilings, roofs and building systems: insulation gaps, framing, air leaks, possible moisture, hot electrical connections, and heating pipes, floors and ducts. For each one it states what the pattern looks like, what it can mean, what else produces it and how it is confirmed.

About House Thermography Reference — published by House Thermography Reference
Document

Contact

Send a correction or a general question about the reference material. No images reviewed, no referrals, no advice on a particular house.

This page is for corrections to the reference material and for general questions about what a thermal pattern can mean. It is not a way to reach a thermographer, an inspector or an energy auditor, and no one here will read, interpret or review a thermal image, an inspection report or an audit about a particular house.

Contact | House Thermography Reference — published by House Thermography Reference