Overview
All of these patterns share one requirement: heat has to be flowing through the shell when the image is taken. That means a steady difference between indoor and outdoor temperature, commonly given as at least 18 degrees Fahrenheit held for several hours, and for exterior images no direct sun for hours beforehand and little wind. In New Hampshire those conditions are easy to meet from late fall through early spring and hard to meet in summer.
Conduction patterns
Heat conducts faster through wood framing than through insulation, and faster still through an empty cavity. On an interior winter image, that shows as a faint grid of studs and plates, which is normal, and as whole stud bays or bands that read colder than their neighbors, which is not. The shapes are crisp and follow the framing. ASTM C1060, the practice for these inspections, emphasizes whether insulation is missing or malfunctioning and says proof requires independent validation, such as a visual check.
Air leakage patterns
Air leaking through the shell draws softer, feathered streaks that follow the air rather than the framing. In a heated house in winter, warm air escapes at the top of the house and cold air is drawn in near the bottom, so the top plates, ceiling penetrations, attic hatch, rim joist and sill are where most leaks show. ASTM E1186, the practices for locating air leakage sites, combines building depressurization with infrared scanning because natural air flows are often too small to find leaks.
The roof as an image
Heat that leaves the living space ends up at the roof deck. A night thermal image of a roof, or simply the pattern of melting snow, shows where it arrives. In a New Hampshire winter that same heat builds ice dams at the eaves, which is why roof patterns sit in this category.
Why the weight varies
Some of these patterns are strong signals: an attic gap can be checked by going into the attic, and a cold rim joist can be seen from the basement. Others need confirming: settled insulation and a top-plate air leak look much alike until a blower door or a look into the cavity separates them. The framing grid is a strong signal of something normal, and its absence on a mild day proves little.
What this category does not include
It does not include moisture, which can mimic missing insulation on a cold day but needs a moisture meter, or the house's own heat sources, such as wiring, pipes, radiant floors and ducts. Those are in the moisture and building systems category.
What to ask about an image in this category
Four questions settle most of what a heat loss or air leakage image can tell you. What were the indoor and outdoor temperatures, and how long had the difference been steady? Was the image taken inside or outside, and if outside, when did the sun last reach that wall? Was a blower door running? And what was done to confirm the pattern: a look into the cavity, a look in the attic, a smoke pencil at the joint? A report that answers all four lets a reader judge the image. A report that answers none leaves a reader with a picture and no way to weigh it.
For a buyer, most findings here are energy, comfort and maintenance items rather than defects: thin attic insulation, a leaky rim joist, a drafty window. Some carry more weight. Roof snowmelt patterns and attic air leaks point toward ice dams and the water damage they cause, and a house with a history of ice dams deserves questions about ceilings and walls near the eaves. For an owner, the sequence energy programs use is the useful one: measure, seal, then insulate, then check the result with a second image under similar conditions.
| Pattern | Weight | Family |
|---|---|---|
| Missing Wall Insulation | A strong signal | Insulation and framing |
| Settled or Compressed Insulation | Needs confirming | Insulation and framing |
| Gaps in Attic Insulation | A strong signal | Insulation and framing |
| Framing Thermal Bridging | A strong signal | Insulation and framing |
| Air Leakage at Wall Tops and Ceiling Edges | Needs confirming | Air leakage |
| Air Leakage at Windows and Doors | Needs confirming | Air leakage |
| Rim Joist and Sill Heat Loss | A strong signal | Air leakage |
| Warm Roof Patches, Snowmelt and Ice Dams | Needs confirming | Air leakage |