House Thermography Reference logo — a house outline shaded from cold to warmHouse Thermography ReferenceWhat an infrared image of a house shows, and what it cannot
After the scan

Blower door and infrared: why energy audits use the two tests together

A thermal camera shows where heat moves. A blower door makes air move on purpose. Together they turn faint, weather-dependent hints of air leakage into clear patterns.

The short answer

A blower door is a calibrated fan fitted into an exterior doorway that pulls air out of a house (depressurization) or pushes it in, while a gauge measures the pressure difference and the airflow. It measures how leaky the house is as a whole. Scanning the interior with a thermal camera while the blower door runs shows where the leaks are: outside air drawn in through gaps cools the surfaces around them. ASTM E1186, the practices for air leakage site detection, includes this combination, and the U.S. Department of Energy describes it as standard energy audit practice. In New Hampshire, the NHSaves utility programs' home energy audits include diagnostic tests to locate air leaks and may use an infrared camera.

Why the camera needs the fan

Air leaks under natural conditions are small and depend on wind and temperature. ASTM E1186, last revised in 2022, says forced air leakage is required because air leakage sites are often difficult to locate when air flows under prevailing weather are small. It notes that the infrared technique has the advantage of rapid surveying, while methods such as smoke tracers are suited to local leak detection. The practices are qualitative: they locate leaks rather than measuring how much air moves through each.

The Department of Energy puts the effect simply: the blower door helps exaggerate air leaking through defects in the building shell, and such leaks appear as dark streaks in the camera's viewfinder.

What the combination shows

Taking images before and during depressurization separates two kinds of pattern. A conduction pattern, such as missing wall insulation or framing thermal bridging, changes little when the fan runs. An air leak grows: streaks lengthen, fan out and get colder. Common finds include top plates and ceiling edges, windows and doors, rim joists and sills, attic hatches, recessed lights, electrical boxes on exterior walls, and chases around chimneys and plumbing.

The fan also lowers the temperature difference a scan needs. Fluke notes that the exaggerated temperature differences a blower door creates let air leakage inspections take place more often through the year.

What the blower door measures

The whole-house number, often air changes per hour at 50 pascals of pressure difference, describes the house's leakiness. It does not say where the leaks are; the camera and smoke do that. Duct leakage is measured with a separate calibrated test on the ducts. See duct leaks and disconnected ducts.

Energy audits in New Hampshire

NHSaves is a collaboration of New Hampshire's electric and natural gas utilities that runs energy efficiency programs. Its Home Energy Performance brochure says the contractor will inspect the attic, basement or crawlspace and run diagnostic tests to locate air leaks, or use an infrared camera to find trouble spots. Program terms, eligibility, copays and incentives change; check the program's current materials before relying on any figure.

The Department of Energy's guidance on choosing an auditor suggests asking whether the auditor uses a calibrated blower door and thermographic inspections, and lists the Building Performance Institute's Home Energy Professional Energy Auditor certification and the Residential Energy Services Network's Home Energy Rater certification among credentials it recognizes.

What happens after

Audits typically recommend sealing air leaks first, especially at the top and bottom of the house, then adding insulation, while checking ventilation and combustion safety. Tightening a house changes how it breathes, and auditors test combustion appliances for safe venting when they tighten a house. A follow-up blower door test and thermal scan after the work are the simplest check that it was done well.

A home inspection is not an energy audit

A home inspection reports on the condition of systems and components under the state's standards of practice. It does not include a blower door test, and New Hampshire's standards do not require thermal imaging. A buyer who wants to know how leaky a house is needs an energy audit. See New Hampshire home inspections and infrared.

Where the guidance comes from

ASTM's summary of E1186-22; the U.S. Department of Energy's Energy Saver guidance on thermographic inspections and professional home energy audits; the NHSaves Home Energy Performance brochure; and Fluke on energy auditing with thermal imagers.

Frequently Asked Questions

What is a blower door test?

A calibrated fan in an exterior doorway changes the house's air pressure, and a gauge measures how much air flows through leaks to maintain that pressure.

Why use a thermal camera with a blower door?

The fan drives air through leaks, which cools the surfaces around them so the camera shows exactly where they are.

Does a home inspection include a blower door test?

No. Blower door testing is part of an energy audit.

Can I get an energy audit through a utility in New Hampshire?

NHSaves, run by the state's electric and gas utilities, offers home energy audit programs. Check its current terms and eligibility.