House Thermography Reference logo — a house outline shaded from cold to warmHouse Thermography ReferenceWhat an infrared image of a house shows, and what it cannot
Line illustration of an elevation of a back porch and its stair representing Air Leakage at Windows and Doors
Heat loss and air leakageAir leakageNeeds confirming

Air Leakage at Windows and Doors

Windows and doors are where a thermal camera finds the most drafts and the most false alarms. Cold glass, reflections and normal frame edges all look like leaks.

What the pattern looks like

A leaking window or door in winter shows on an interior thermal image as cold air spilling from a joint. Typical shapes are a cold tongue running down the wall below a sash, a cold strip along the meeting rail of a double-hung window, a fan of cold spreading across the floor from under an exterior door, or cold streaks around the casing where the gap between the window frame and the rough opening was never sealed.

As with all air leakage, the edges are soft and the shape follows the air.

The patterns that are normal

Glass is colder than walls. Even good double or triple glazing insulates far less than a wall, so a window always reads colder than the wall around it in winter.

Glass edges are colder than glass centers. Insulated glass units have a spacer around their edge that conducts more heat than the gas-filled center. A cold band a few inches wide around the perimeter of each pane is expected.

Frames vary. Aluminum frames read colder than wood or vinyl. Hardware, locks and hinges are metal and read differently.

None of these is a leak.

Why glass is hard for a thermal camera

Glass is nearly opaque to the long-wave infrared that building cameras use, so the camera sees the surface of the glass, not through it. Glass is also reflective in the infrared. A camera pointed at a window can show the thermographer's own body, a heat register, a lamp or the cold night sky reflected in the pane. Polished or anodized metal frames reflect too. The guide to emissivity and reflections explains why, and why changing the viewing angle is the quickest check: a reflection moves when the camera moves; a real temperature pattern does not.

Why a blower door helps

Many window leaks are small under natural conditions. ASTM E1186, the practices for locating air leakage sites, includes depressurization combined with infrared scanning, and notes that forced air leakage is needed because natural air flows may be too small to locate leaks. With a blower door running, a leaking sash or an unsealed casing shows a cold streak that grows; a cold pane does not change shape.

What else produces a similar pattern

A heat register below the window. Warm supply air washing up the glass can make the frame warmer and the wall above streaked.

Sun earlier in the day. A south-facing frame warmed by afternoon sun stays warm into the evening.

Condensation and frost. Wet sills and frosted glass evaporate and read cold, which can look like a leak. See cold corners and condensation.

How it is confirmed

Look at the weatherstripping: is it compressed, torn or missing? Close the window fully and check the lock pulls the sashes tight. Remove a piece of interior trim, or look from the basement or attic where possible, to see whether the gap around the frame was sealed. A smoke pencil at the joint on a windy day shows air movement directly.

Common mistakes

Replacing windows for an air leak. Many leaks are at the weatherstripping or at the unsealed gap around the frame. Both can be repaired without new windows.

Reading a reflection as a hot spot. Move and look again.

Reading every cold window as a problem. Glass is cold in winter. The question is whether air is moving.

What to do with it

Separate the findings into three groups: weatherstripping and adjustment, which are maintenance; unsealed frame gaps, which are air sealing work; and failed glass units, which show as fogging between panes rather than on a thermal image. Ask the thermographer which group each finding belongs to. For a house-wide view of where air enters and leaves, a blower door audit is more informative than a window-by-window scan.

Where the guidance comes from

The practices for locating air leakage, including forced leakage with infrared scanning, are summarized in ASTM's listing of E1186-22. Teledyne FLIR explains reflected temperature and low-emissivity surfaces in How does emissivity affect thermal imaging?. The U.S. Department of Energy describes blower door and thermal scans together in its Energy Saver guidance.

Frequently Asked Questions

Can a thermal camera see through a window?

No. Building thermal cameras cannot see through ordinary glass. They read the glass surface, and glass also reflects infrared.

Why is the edge of my window glass colder than the middle?

The spacer around the edge of an insulated glass unit conducts more heat than the gas-filled center. A cold edge band is normal.

Do I need new windows if the thermal image shows drafts?

Not necessarily. Many leaks are at worn weatherstripping or at the unsealed gap between the frame and the wall, which can be repaired.

How can I tell a reflection from a real hot spot?

Move the camera and look again from a different angle. A reflection moves with you; a real temperature pattern stays put.