What the pattern looks like
Hot water (hydronic) heating, with a boiler circulating water through baseboard convectors, cast-iron radiators or radiant tubing, is common in New Hampshire. With the system calling for heat, a thermal image shows every working emitter as warm: baseboard runs as long warm bands at the base of walls, radiators as warm blocks, and the pipes feeding them as warm lines along basement ceilings, up walls and across floors. At the boiler, the supply pipe reads hotter than the return, since the water gives up heat on its way around.
What the camera reads well
Flow. A baseboard that warms along its length is getting hot water. One that stays cold, or warms only at one end, is not.
Air. In a cast-iron radiator or a high baseboard run, air collects at the top. A radiator that reads warm at the bottom and cold at the top is a classic sign that it needs bleeding.
Zones. Houses with several zones show each zone warming when its thermostat calls. A zone that never warms points to a thermostat, a zone valve or a circulator pump.
Hidden routes. Supply and return pipes buried in walls or floors draw warm lines when the system runs. That is useful before cutting into a wall, and it shows where pipes run along exterior walls where they are at risk of freezing.
What the camera cannot judge
A thermal image of a boiler shows its jacket and piping temperatures. It does not test combustion, carbon monoxide, venting, the condition of the heat exchanger or the safety controls. A boiler with a warm, even jacket is not shown to be safe. That evaluation belongs to a licensed heating technician.
Freezing risk
The same image that shows working baseboards shows pipes in cold places: a baseboard on an outside wall over an uninsulated rim joist, piping in an unheated garage or crawlspace, a run through a cold overhang. In a house left with the heat low, those are where a pipe freezes first. See rim joist heat loss.
What else produces a similar pattern
Domestic hot water lines. Hot water supply pipes look like heating pipes. Running a tap and watching which line warms separates them. See hidden plumbing leaks.
Radiant floors. Tubing in floors shows as a different pattern of loops and lines. See radiant floor heat patterns.
Low-emissivity metal. Bare copper and polished fittings reflect their surroundings and read lower than their true temperature. Painted pipe and the baseboard's painted cover read far more reliably. See emissivity and reflections.
What New Hampshire inspectors do
New Hampshire's standards of practice, in Home 603.02 of the administrative rules, set out what the home inspector must inspect in the heating system, and say the inspector need not determine heat supply adequacy or distribution balance. A thermal camera shows distribution clearly, but judging whether a system delivers enough heat for a house is beyond the standard and depends on heat loss calculations.
Common mistakes
Scanning with the system off. Nothing shows. The thermostat has to call for heat for long enough to warm the loop.
Reading bare copper temperatures. Shiny pipe reads low; check a painted section or a fitting with tape on it.
Equating a warm boiler with a safe boiler. Combustion safety is a separate test.
What to do with it
For a buyer, a hydronic system that warms every emitter during the inspection is a good sign. Ask for the boiler's service records and have a technician check combustion and safety controls if they are unknown. For an owner, a cold radiator usually needs bleeding; a cold zone usually needs a technician to look at the valve, the pump or the thermostat.
Where the guidance comes from
The New Hampshire standards, including the distribution balance limitation, are in the Home 100-700 rules. Teledyne FLIR explains emissivity and reflection in How does emissivity affect thermal imaging?. HUD's research office describes identifying hot-water piping in Thermal Imaging for Building Diagnostics.