What the pattern looks like
From outside on a cold, still night, a thermal image of a pitched roof over a well-insulated, well-sealed attic reads cold and fairly even, close to the night sky's influence. Warm patches show where heat from the house is reaching the roof deck: a stripe above a ridge where warm air leaks through, rectangles above a bathroom fan or an uninsulated hatch, streaks above a chimney chase or a duct run.
After a snowfall the same pattern appears without a camera. Snow melts first over the warm patches, leaving bare shingles in the shape of the heat leaks, while the overhangs stay snow-covered and cold.
How snowmelt becomes an ice dam
The University of Minnesota Extension sets out the conditions. For ice dams to form there must be snow on the roof and, at the same time, higher portions of the roof's outside surface must be above 32 °F while lower surfaces are below 32 °F. Meltwater from the warm upper roof runs down to the cold eaves and refreezes, building a ridge of ice that holds back more water. That water can then work under shingles and leak into walls and ceilings.
The Extension is clear about the source of the heat: it is primarily heat flowing from the house, by conduction through the ceiling and its insulation, by convection, and by air leakage into the attic. Uninsulated or leaky ductwork in the attic, and chimneys, add more. The guide to ice dams and attic heat loss follows the problem from the living space to the gutter.
Why the roof image needs the attic image
A roof image shows where heat arrives at the roof. It does not show whether the heat got there through missing insulation, an air leak, a duct or a chimney chase. The attic tells you that. A thermographer who sees a warm stripe on the roof should go into the attic and look at the matching spot for disturbed insulation, an open chase or a disconnected duct. See attic insulation gaps and duct leaks and disconnected ducts.
Conditions for an exterior roof scan
Exterior building thermography depends heavily on weather. The Snell Group reports that ASTM C1060, the practice for thermographic inspection of insulation, specifies no direct sun on exterior surfaces for at least three hours before the inspection and no inspection in winds above 15 mph. Sun warms shingles unevenly for hours, and wind strips heat from the surface. Night, cloud or early morning before sunrise give the cleanest roof images. A roof also faces the cold night sky, which pulls its surface temperature down and can reflect in the image.
What else produces warm roof patches
Sun earlier in the day. South-facing slopes, dark shingles and areas shaded at different times hold heat differently.
Vents and stacks. Plumbing vents, flues and exhaust terminations are warm by design.
Materials. Flashing and metal accessories have low emissivity and read unreliably. See the guide to emissivity and reflections.
Wet insulation on a low-slope roof. On flat and low-slope roofs, a warm patch after sunset can mean wet insulation holding the day's heat. That is a different survey. See wet insulation in a low-slope roof.
Common mistakes
Adding attic fans to stop ice dams. The University of Minnesota Extension advises that mechanical attic ventilation is not a recommended solution to ice dams in Minnesota, as it can create other moisture problems and negative pressure in the home. Sealing and insulating the ceiling deals with the source.
Treating heat cables as the fix. Heat cables manage meltwater at the eaves. They do not reduce the heat loss that causes the problem.
Scanning in the afternoon. A sunny afternoon scan of a roof shows the sun, not the house.
What to do with it
For a buyer, ask about past ice dams and look for staining at ceilings near exterior walls. A roof that sheds snow in patches while its neighbors are still white is telling you something about the attic. For an owner, start with an energy audit that includes attic air sealing, then insulation, and check any ducts or bath fans in the attic.
Where the guidance comes from
The ice dam conditions and the sources of attic heat are from the University of Minnesota Extension. The exterior survey conditions are The Snell Group's account of ASTM C1060. The U.S. Department of Energy describes exterior and interior surveys in its Energy Saver guidance.