House Thermography Reference logo — a house outline shaded from cold to warmHouse Thermography ReferenceWhat an infrared image of a house shows, and what it cannot
Infrared in a home inspection

Thermographer training: what Level I, II and III mean, and what a home inspector's certificate covers

No state licenses thermographers. Credentials come from private training bodies, and they range from a few hours online to weeks of classroom and field work.

The short answer

Thermography is certified privately, not by a state. The best-known structure has three levels. Level I covers camera operation, data collection and basic interpretation. Level II adds measurement accuracy, more applications and diagnosis. Level III is for program managers who write procedures and supervise others. Training bodies such as the Infrared Training Center base these levels on the American Society for Nondestructive Testing's recommended practice SNT-TC-1A and its topical outline CP-105, and on ISO 18436-7 for thermography personnel. Home inspector associations offer shorter thermography courses aimed at residential work. New Hampshire's home inspector license does not require any of them.

The levels

The Infrared Training Center, one of the largest certification bodies, describes the levels this way. Level I is designed for new thermographers and focuses on camera operation, basic physics and image interpretation. Level II is for experienced thermographers and troubleshooters; a Level II thermographer typically uses more than one diagnostic technology to determine the root cause of a problem and recommend repairs, and is qualified to give technical direction to Level I personnel. Level III is the most advanced, aimed at the thermographer who manages a program and writes procedures. ITC certifications are valid for five years and must be renewed.

Other training firms, such as The Snell Group and the Infraspection Institute, offer level-based courses too, and some offer application-specific courses for electrical, mechanical or building work.

The standards behind the levels

ASNT SNT-TC-1A is a recommended practice for qualifying and certifying nondestructive testing personnel, under which an employer certifies its own staff against a written practice. ANSI/ASNT CP-105 gives topical outlines for each method, including infrared and thermal testing. ISO 18436-7 sets requirements for qualification and assessment of thermography personnel in condition monitoring. ISO 6781-1:2023, the building thermography standard, lists qualifications of equipment operators, image analysts, report authors and those making recommendations among the things a thermographic service should specify.

Home inspector courses

Home inspector associations offer thermography training aimed at residential use. InterNACHI, for example, offers an Infrared Certified designation that requires completing its inspector certification and its thermography inspector course, or one of several listed outside courses. These courses teach building science, camera use and the common residential patterns. They are generally shorter than a multi-day Level I class.

The difference matters most where a finding turns on measurement: electrical thermography, where temperatures on shiny components need careful handling, and roof moisture surveys under ASTM C1153, which addresses operator qualifications directly.

What New Hampshire requires

New Hampshire licenses home inspectors under RSA 310-A:189, and its standards of practice do not mention thermal imaging. There is no separate state credential for thermographers. An inspector's thermal images carry whatever weight the inspector's training and method give them. See New Hampshire home inspections and infrared.

What to ask

What thermography training have you completed, from whom and when? Is it current? Have you done electrical work under load, and do you follow a written procedure? How do you confirm moisture findings? Do your reports record conditions? An inspector or auditor with real training answers these easily, and the answers tell you how much weight to put on the images.

Training is not the whole story

A certificate shows that someone completed a course. Good thermal work also needs the right conditions, a capable camera, a method, and the discipline to confirm findings before reporting them as fact. A Level II thermographer scanning a wall on a mild afternoon will see as little as anyone else. See temperature difference and timing and camera resolution and specifications.

Where the guidance comes from

The Infrared Training Center's certification page describes its levels and the standards behind them. InterNACHI's Infrared Certified requirements describe its designation. ISO's listing for ISO 6781-1:2023 sets out the qualifications a thermographic service should specify.

Frequently Asked Questions

Do thermographers need a license?

No state license is required for thermography as such. Certification comes from private training bodies.

What is a Level I thermographer?

Someone trained and certified in camera operation, data collection and basic interpretation, usually after a multi-day course based on ASNT and ISO outlines.

Is a home inspector's infrared certificate the same as Level I?

Not usually. Inspector association courses are aimed at residential use and are generally shorter. Ask what the course covered.

How long does thermography certification last?

It depends on the body. The Infrared Training Center's certifications are valid for five years.