House Thermography Reference logo — a house outline shaded from cold to warmHouse Thermography ReferenceWhat an infrared image of a house shows, and what it cannot
How thermal imaging works

Temperature difference, sun and wind: when a thermal scan of a house can work

A thermal camera reads heat flow through a building, and no heat flow means no picture. Most failed building scans fail on conditions, not on the camera.

The short answer

Envelope thermography, the work of finding insulation gaps and air leaks, depends on heat flowing through walls and ceilings. That needs a meaningful, steady difference between indoor and outdoor temperature, usually written delta-T (ΔT). Fluke's inspection guidance asks for at least 18 °F (10 °C) between interior and exterior surfaces, held stable for at least four hours where possible. Testo's practical guide asks for 10 to 15 °C over at least 12 hours. Exterior scans also need the surface shielded from sun for hours beforehand and low wind. In New Hampshire, the heating season meets these conditions most days; summer rarely does.

Why the difference matters

A thermal camera measures surface temperature. A wall's inside surface differs from one area to the next only when heat is passing through the wall unevenly: faster through a stud, faster still through an empty cavity, slower through a well-insulated one. If indoor and outdoor temperatures are close, heat flow is small everywhere, and the surface reads evenly whatever is inside the wall.

The difference also has to be steady. Walls store heat. A cold snap that started an hour ago has not yet worked through the wall, and a sunny afternoon followed by a cold evening leaves a wall still giving up the day's heat.

The framing check

Trade guidance offers a quick test: look for the framing. If the studs and plates show as a faint grid on an interior winter image, there is enough heat flow to reveal anomalies. If the framing cannot be seen at all, conditions are probably inadequate to see problems either. See framing thermal bridging.

Sun

Sunlight heats exterior surfaces unevenly, and dark materials absorb more than light ones. The Snell Group reports that ASTM C1060, the practice for thermographic inspection of insulation, specifies no direct solar exposure on exterior surfaces for a minimum of three hours before an inspection. Testo's guide recommends exterior building work in the cold season in the morning before sunrise. A south wall imaged in the evening after a sunny day mostly shows where the sun was.

Sun also affects interior work: a wall warmed on its outside face during the day reads warmer inside into the evening, and sunlight through a window warms floors and furniture.

Wind

Wind strips heat from exterior surfaces and pushes air through the building. The Snell Group reports that C1060 specifies no inspection in winds above 15 mph. Testo's guide gives below 5 meters per second, about 11 mph. For interior air leakage work, a moderate wind can help by driving air through leaks, which is why ASTM E1186, the air leakage practices, notes that wind conditions can aid detection. The controlled alternative is a blower door. See the guide to blower door and infrared testing.

Moisture work is different

Finding wet materials does not depend on indoor-outdoor ΔT in the same way. Wet surfaces read cool through evaporation, and they change temperature more slowly than dry ones. Moisture surveys can be done in any season, with care about what heated or cooled the surface. Night roof moisture surveys under ASTM C1153 depend on a sunny day followed by a clear night. See wet insulation in a low-slope roof.

Electrical work is different again

Electrical thermography depends on load, not weather. A connection heats when current flows. See a hot breaker or connection.

New Hampshire seasons

New Hampshire's climate is cold: under the state's energy code, Cheshire, Hillsborough, Rockingham and Strafford counties are in climate zone 5 and the rest of the state is in zone 6. From November through March, an indoor temperature of 68 °F against outdoor temperatures in the 20s and 30s gives a ΔT of 30 °F or more for days at a time, ideal for envelope work. Spring and fall nights often work; days often do not. Summer air conditioning can create a reversed ΔT, but it is small and the sun dominates.

A home inspection is scheduled around a sale, not around weather, so the thermal images in a summer inspection report may show little about insulation. That is a limit of the conditions, not of the inspector.

What a good report records

Fluke's checklist lists what to record: interior and exterior air temperature and humidity, weather conditions including sun and precipitation, and wind direction and speed. A thermal report that omits conditions gives a reader no way to judge whether a clean image means a good wall or no heat flow.

Where the guidance comes from

Fluke's thermal imaging inspection checklist, Testo's building thermography practical guide, The Snell Group's account of ASTM C1060 conditions, and ASTM's summary of E1186-22.

Frequently Asked Questions

What temperature difference does a thermal scan of a house need?

Commonly cited guidance is at least 18 °F (10 °C) between inside and outside, held steady for several hours.

Can a thermal scan be done in summer?

Moisture and electrical scans can. Insulation and air leakage scans are much less reliable because the temperature difference is small and the sun distorts exterior surfaces.

Why do exterior scans happen before sunrise?

Sunlight heats surfaces unevenly for hours. Before sunrise, after a cold night, the house is the main heat source.

Does wind ruin a thermal scan?

Strong wind cools exterior surfaces and distorts exterior images. A moderate wind can help reveal air leaks from inside.